LED Installation Issues

Posted on under Installations

 

I have noted an article described as an advertorial in the 2016 July – August NECA NEWS (page 13)  regarding LED Power Supplies which I believe is a very important article for commercial electricians in Sydney to understand and take important care in choosing LED lighting fixtures & associated controls.

In particular, it is very important for the LED fixtures & controls to have been approved by the Australian Standards to ensure that imported products are suitable for installation within Australia. Otherwise, various products suitable for other countries may cause early expensive failures of the light fixtures and the controls connected to the LED circuits.

Apart from providing electrical installations, Caslec also provides electrical maintenance services and recently a Caslec service technician was required to attend a large new LED lighting installation installed by another contractor who was having technical issues. Commercial electricians from Caslec in Sydney observed that the LED lighting installation & the general installation equipment and distribution switchboards were of a high standard, however, there were issues with circuit breakers tripping and several failed contactors at the lighting distribution switchboard.

Various tests were performed & it was concluded that the electronic drivers were permitting considerable inrush currents as can be seen within this particular graphic image, over a page. One 60 Watt LED light fixture was producing an inrush current of 39 Amps. This may only be for a minimal period however when there are a number of light fixtures connected to the circuit, as in this case, the inrush current is considerable, particularly at the maximum level of the switching cycle. One of the commercial electricians from Caslec created a graph that clearly displays the level of start current that is drawn by a single light fixture during start up. As an example, 10 light fixtures on one circuit will certainly strain any normal lighting circuit including the controls, even during a minimal section of a single cycle.

The light fixture drivers external to the light fixtures were not approved for Australian installations resulting in costly replacements, even though the LED fixture itself is certainly of high quality. LED’s are the new lighting technology that is being embraced by almost everyone in Australia but they are not simple incandescent globes or fluorescent lamps. LED’s emit light but are grouped with other electronic components & devices, including additional controls that are associated with these devices.

The controls have to relate to the LED’s and the actual incoming power supplies within Australia & conform to Australian Standards.

For more information, contact commercial electricians from Caslec.

New Rules on Fluorescent Lamps

Posted on under Installations, Tips

The Federal Governments wants everyone to reduce energy usage & improve sustainability & toward that effort, costly recycling of fluorescent lamps will become compulsory with a few years due to the Mercury content in fluorescent lamps.

As well, customers will benefit from reduced power consumption and cost savings by replacing standard 36 watt fluro tubes with 16 Watt LED tubes. LED tubes have a very long lasting rated life of 40,000 hours as opposed to fluro tubes with 12,000 -15000 hours. Reduced maintenance costs are also a big benefit. Very importantly there is no Mercury content in LED lamps as there is in fluro lamps.

Lots of things are happening with new lighting technology. Call Caslec on for further details.

Halogen Downlights – Safety Alert

Posted on under General News, Installations

The usual & very popular 50 Watt Halogen lights are no longer sold in Australia due to the number of fires caused in the ceilings of homes as a result of the heat that is produce from each lamp. Minimise the cause of such fires by installing heat shields over each fixture.
Alternatively, replace those light fixtures with the new technology, LED fixtures. LED’s will reduce the heat that is generated from Halogen downlights & at the same time reduce your power costs.

Call our Installation Dept for further particulars.